Fall Protection Anchors For Fabral Standing Seam Systems
Posted by Howie Scarboro - CEO Fall Protection Distributors, LLC on Nov 13th 2025
See the Roof Anchor Compatibility Chart for Fabral Standing Seam Panels.</p >

Who Is Fabral Roofing Systems?
Fabral has shaped the American metal roofing industry for more than fifty years. Founded in 1967, the company began as a regional supplier of durable steel panels.
It grew into one of the nation's most respected names in metal building systems. From its early contributions during the Vietnam War to its leadership in today's energy-efficient construction movement, Fabral has built a reputation for craftsmanship, quality, and performance.
Headquartered in Lancaster, Pennsylvania, Fabral Roofing Systems manufactures lightweight, weather-resistant, and environmentally responsible metal panels used across agricultural, residential, commercial, and architectural projects. Each panel is made from partially recycled steel and is fully recyclable at the end of its lifespan, supporting LEED certification and long-term sustainability goals. Fabral also offers user-friendly design tools, such as the Fabral Color Visualizer, which helps architects and contractors preview color and finish combinations for roofing and wall systems.
In 2023, Flack Global Metals (FGM) acquired Fabral, marking its strategic entry into manufacturing. The acquisition also included CopperCraft, Fabral's architectural metals brand, expanding product capabilities for decorative and high-performance applications. Today, Fabral operates eight facilities across the United States, employs more than 200 specialists, and serves over 500 customers nationwide, maintaining its position as a trusted supplier in the metal building industry.

Why Are Non-Penetrating Fall Protection Anchors Critical For Fabral Standing Seam Roofs?
Non-penetrating fall protection anchors protect Fabral standing seam roof systems by maintaining weather-tight performance and full OSHA compliance.
Working safely on Fabral standing seam roofs requires fall protection systems that secure workers without damaging the panels. Because Fabral's roofs are floating systems, the seams and concealed clips expand slightly as temperatures change. Drilling or screwing directly into the panels restricts that movement, eventually leading to leaks, oil-canning, and loss of warranty coverage.
Non-penetrating anchors such as the SSRA1 Standing Seam Roof Anchor, SSRA2 Adjustable Roof Jack Adapters, and SSRA3 Anchor Plate attach directly to the seams with stainless steel screws that grip securely without piercing the metal. This system preserves the panel finish, maintains the floating design, and keeps each roof fully compliant with OSHA and ANSI standards.
For large or multi-worker projects, the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit allows two workers to remain tied off across long roof spans while maintaining continuous mobility. For facilities that require ongoing roof access, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit provides a fixed tie-off solution that stays in place for long-term maintenance.
On steeper Fabral roofs with slopes between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor provides a secure, ridge-mounted connection that installs quickly without drilling. It allows workers to attach their lifeline before stepping onto the roof, ensuring a 100 percent tie-off from the ladder to the ridge and back again.
By pairing Fabral's standing seam roof systems with non-penetrating fall protection anchors, contractors can protect the structure, preserve warranties, and ensure total worker safety across every jobsite.
Horizon S Snaplock Panels

Horizon S snaplock panels offer a lightweight residential standing-seam system for fast installation and long-term curb appeal.
The Horizon S Snaplock Panel remains one of Fabral's most popular standing seam systems, especially for residential, post-frame, and light commercial construction. The 16-inch panel width and 1-inch seam height create a clean profile that fits traditional and modern home designs. A built-in nailstrip flange allows installers to fasten the panel directly to solid decking, making the system a popular choice for homeowners and small crews who prefer a simplified installation process without specialized seaming tools.See the Roof Anchor Compatibility Chart for Fabral Horizon S Standing Seam Panels.
Fabral produces Horizon S in 26-gauge steel, keeping the panel lightweight while still offering notable durability in everyday weather conditions. With a minimum roof pitch requirement of 3:12, Horizon S moves water efficiently and provides reliable performance for residential structures, barns, garages, porches, and similar projects where aesthetics and value matter.
Fall Protection For Horizon S Panels
Fall protection for Horizon S panels relies on ridge-mounted systems that protect lightweight 26-gauge steel without deforming the seams.
Because Horizon S panels are 26-gauge steel, they lack the structural rigidity required to support clamp-style anchorage. Products such as the SSRA1 Standing Seam Roof Anchor, SSRA2 Adjustable Roof Jack Adapter, and SSRA3 Anchor Plate require thicker metal for proper seam attachment.
For Horizon S roof systems, the safest and most reliable solution is the Ridge Pro Steep Assist Anchor for 6:12- and 12:12-pitched roofs. The Ridge Pro hooks over the roof peak and creates a non-penetrating tie-off point that does not rely on seam attachment. This design shields the lightweight panel from unnecessary stress while providing a stable connection point before the worker ever steps onto the metal surface.
The Ridge Pro keeps workers protected from the ladder to the peak and back down again. It installs quickly, leaves no marks on the roof, and offers a straightforward approach for inspections, minor repairs, and short-duration service work on Horizon S structures.
Horizon S100 Snaplock Nailstrip Panels

Horizon S100 snaplock nailstrip panels provide a lightweight standing seam option, ideal for residential applications and straightforward installation.
The Horizon S100 Snaplock Nailstrip Panel expands Fabral's residential lineup by blending visual appeal with practical installation features. This system keeps the familiar 16-inch panel width and the 1-inch seam height that homeowners appreciate, while incorporating a revised nailstrip configuration that speeds installation on solid decking. The snap-together seam locks cleanly into place, creating a smooth finish that strengthens curb appeal on post-frame buildings, cabins, garages, and light commercial structures. See the Roof Anchor Compatibility Chart for Fabral Horizon S100 Standing Seam Panels.
Fabral manufactures the Horizon S100 in 26-gauge steel, keeping the panel lightweight while offering dependable protection in everyday weather conditions. Shadow lines formed during roll-forming add extra dimension to the roof surface, giving the panel a more refined architectural look. With its minimum recommended pitch of 3:12, the S100 provides reliable water shedding and long-term performance for residential and agricultural roof designs where cost and appearance matter.
Fall Protection For S100 Panels
S100 snaplock nailstrip roofs require ridge-mounted fall protection systems that safeguard thin-gauge metal without stressing the seams.
Because the Horizon S100 is 26-gauge steel, it does not provide the required seam strength for clamp-based fall protection. Non-penetrating anchors such as the SSRA1 Standing Seam Roof Anchor, SSRA2 Adjustable Roof Jack Adapter, and SSRA3 Anchor Plate rely on thicker panel materials to withstand impact loads from a fall.
For the S100 system, the most dependable choice is the Ridge Pro Steep Assist Anchor on slopes between 6:12 and 12:12. The Ridge Pro locks over the roof peak. It provides a connection point without clamping the seams or driving fasteners through the deck. Workers attach their lifeline from the ladder before stepping onto the roof, giving them continuous tie-off throughout the job.
This method protects thin-gauge metal, maintains the panel's finish, and provides a non-penetrating fall protection strategy for installations, inspections, and service work on Horizon S100 roofs.
Horizon 16 Snaplock Nailstrip Panels

Horizon 16 snaplock nailstrip panels deliver a clean residential profile with simple installation and reliable performance on solid decking.
The Horizon 16 Snaplock Nailstrip Panel rounds out Fabral's residential standing seam lineup with a profile tailored for homeowners, remodelers, and light commercial builders who want a clean architectural look without complicated tools. This panel keeps the familiar 16-inch width and 1-inch seam height. It uses a nailstrip and snaplock seam to speed up installation and reduce labor time. It seats firmly over solid decking and locks into place for superior appearance and weather protection. See the Roof Anchor Compatibility Chart for Fabral Horizon 16 Standing Seam Panels.
Fabral's Horizon 16 is made from 26-gauge steel, keeping the panel lightweight enough for small crews to handle while still offering dependable strength for long-term residential use. Standard stiffening ribs run through the pan and add subtle definition to the roof surface, giving the panel a more refined appearance. With a minimum pitch requirement of 3:12, the Horizon 16 sheds water effectively. It performs well on homes, post-frame buildings, garages, and light commercial structures where cost, style, and ease of installation all matter.
Fall Protection For Horizon 16 Panels
Horizon 16 roofs require ridge-based anchorage because the thin 26-gauge steel cannot support a seam-mounted clamp-style fall protection system.
Because the Horizon 16 panel is 26-gauge steel, the seams do not provide sufficient strength for clamp-on anchorage, such as the SSRA1, SSRA2, or SSRA3 components. Using seam-mounted anchors on thin metal substrates increases the risk of panel deformation and voided warranties, so a different approach is required.
For this profile, the most dependable method is the Ridge Pro Steep Assist Anchor when working on slopes between 6:12 and 12:12. The Ridge Pro hooks over the ridge. It creates a stable tie-off point before the worker even steps onto the metal surface. This setup keeps the panel seams untouched, protects the roof finish, and provides continuous tie-off during climbing, movement, and descent.
The simplicity of the Ridge Pro makes it especially useful for residential service work, minor repairs, or installation tasks that require fast access without altering the roof structure.
1-1/2-inch SSR Snaplock Panels

Fabral's 1-1/2-inch SSR snaplock panel provides structural strength, wide coverage, and low-slope performance for commercial and residential metal roofs.
The Fabral 1-1/2-inch SSR Snaplock Panel delivers a structural standing seam profile that bridges the gap between residential simplicity and commercial performance. Fabral forms these panels from 24-gauge steel, which gives them a noticeably stronger feel and better resistance to foot traffic than the lighter 26-gauge Horizon profiles. Each panel covers 16 inches, snapping securely into the next with a 1-1/2 inch seam that locks tightly without the need for mechanical seaming. See the Roof Anchor Compatibility Chart for Fabral 1-1/2-inch SSR Snaplock 24 gauge Standing Seam Panels.
A factory-applied seam sealant runs the length of the panel, allowing installation on slopes as low as 1:12, which is unusual for a snaplock system and makes it a practical choice for large commercial buildings, long runs of roofing, or retrofit projects where slope limitations exist. Standard shadow lines add stiffness to the pan while also giving the roof a more defined, dimensional appearance. Whether installed over solid decking or used to recover an existing roof, this panel offers the structural stability builders expect from a higher-gauge system.
Fall Protection For 1-1/2-inch SSR Snaplock Panels
1-1/2 inch SSR panels support full SSRA compatibility, allowing crews to use seam clamps, walk boards, and horizontal lifelines without penetrating the roof.
Fabral's 1-1/2-inch SSR Snaplock profile is 24-gauge steel, which meets the strength threshold needed for non-penetrating SSRA equipment. This sturdy panel allows workers to use the complete SSRA system safely and effectively.
The SSRA1 Standing Seam Roof Anchor grips the 1-1/2-inch seam with 12 non-penetrating set screws. The anchor provides a single tie-off point rated to 5,000 pounds without penetrating the panels. Its secure attachment method is ideal for inspections, installation work, or long maintenance intervals.
For extended access, the SSRA2 Adjustable Roof Jack Adapter mounts on top of two SSRA1s to support a 10-foot walk board. The SSRA2 is adjustable for various seam heights and roof pitches.
Crews needing mobility along long roof runs can use the SSRA3 Anchor Plate, which joins two SSRA1 anchors into a solid foundation for a horizontal lifeline. When paired with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, which includes two SSRA3s, four SSRA1s, and the Malta Dynamics HLL3001 system, two workers can travel freely while staying continuously tied off.
Facilities that receive ongoing service benefit from the Super Anchor 120-foot Permanent Horizontal Lifeline Kit, which installs once and remains in place for long-term anchorage. This kit protects the roof's weather-tight assembly while eliminating the need for repeated setup.
If the roof pitch falls between 6:12 and 12:12, crews can also use the Ridge Pro Steep Assist Anchor. This tool hooks over the ridge and allows the lifeline to be attached before the worker steps onto the roof surface. On tall, steep SSR projects, it becomes a fast way to gain initial access without modifying the panel seams.
1-1/2-inch SSR 150 Snaplock Panels

Fabral's SSR 150 snaplock panel blends structural performance, low-slope capability, and long panel lengths for demanding residential and light commercial projects.
The Fabral 1-1/2-inch SSR 150 Snaplock Panel delivers a structural-grade roofing solution built for long-term durability and consistent weather performance. Fabral rolls this panel from 24-gauge steel, providing the rigidity needed for structural applications that require accounting for wind, snow, and thermal movement. A factory-applied sealant inside the seam, combined with the snaplock profile, provides reliable watertightness on slopes as low as 1:12, making this one of Fabral's most versatile low-slope options. See the Roof Anchor Compatibility Chart for Fabral 1-1/2-inch SSR 150 Snaplock 24 gauge Standing Seam Panels.
Each panel offers 16 inches of coverage with a 1-1/2 inch seam height, creating a defined profile that installs cleanly across long roof spans. Fabral also offers factory notching, which speeds up eave hemming and produces a clean, finished edge. With panel lengths up to 40 feet, builders can minimize end laps and maintain the structural integrity expected from a Class 90 wind-rated roof system.
The SSR 150 carries multiple performance certifications, including UL2218 Class 4 hail impact resistance, UL790 Class A fire rating, and UL580 Class 90 uplift performance. These high-level ratings make the panel suitable for regions with frequent storms, heavy temperature shifts, or strict building code requirements.
Fall Protection For 1-1/2-inch SSR 150 Snaplock Panels
The SSR 150's 24-gauge steel seams support full SSRA compatibility, enabling safe use of seam-mounted anchors, walk boards, and horizontal lifelines without roof penetrations.
Because the SSR 150 panel is 24-gauge structural steel, it is strong enough for the full suite of SSRA non-penetrating fall protection systems.
The SSRA1 Standing Seam Roof Anchor grips the 1-1/2-inch seam with low-torque set screws, providing secure holding without penetrating the roof. This seam anchor creates a dependable 5,000-pound anchorage point for fall arrest while preserving the panel's weather-tight construction.
For crews that must move materials or maintain footing on steep roof runs, the SSRA2 Adjustable Roof Jack Adapter mounts directly to two SSRA1 anchors. Its height-adjustable legs align with the taller SSR 150 rib, creating a stable, level platform for 10-foot walk boards. This setup reduces worker fatigue and keeps tools and materials secure during installation or repairs.
When horizontal mobility is required, the SSRA3 Anchor Plate joins two SSRA1s to anchor the lifeline system. The SSR 150's seam gives the SSRA3 a balanced clamping surface, making it ideal for extended roof access. When combined with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, which includes two SSRA3 plates, four SSRA1 anchors, and the Malta Dynamics HLL3001, the system provides continuous tie-off for two workers across wide roof areas.
For facilities that require frequent rooftop access, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit provides a long-term anchorage solution that remains in place year-round. It distributes forces across multiple SSRA1 anchors and preserves the roof's warranty by avoiding penetrations entirely.
If the roof pitch is between 6:12 and 12:12, crews can also rely on the Ridge Pro Steep Assist Anchor. This ridge-hook device allows workers to attach their lifeline before stepping onto the metal surface, making steep-slope access safer on initial ascent and descent.
2-1/2-inch SSR Batten T-Seam Panels

Fabral's tall 2-1/2-inch batten seam panel delivers structural strength, low-slope performance, and a wide range of material options for demanding architectural metal roofs.
The Fabral 2-1/2-inch SSR Batten T-Seam Panel stands out for its tall rib profile and ability to handle extremely low slopes. Each panel provides 18 inches of coverage and rises to a 2-1/2 inch seam height, creating a deep, bold shadow line favored in modern commercial and institutional designs. The elevated seam allows this system to function on slopes as low as ½:12, an advantage for buildings that require long drainage runs or architectural continuity across shallow roof pitches. See the Roof Anchor Compatibility Chart for Fabral 2-1/2-inch SSR Batten T-Seam 22 gauge and 24 gauge Standing Seam Panels.
Fabral manufactures this panel in a wide range of base metals, including 18, 20, 22, and 24 gauge steel, as well as .032, .040, and .050 aluminum for corrosion-prone environments. These options give architects flexibility in weight, strength, and aesthetics. At the same time, the batten-style T-seam delivers mechanical stability across long panel lengths. The tall rib design also enhances the panel's ability to resist wind uplift and water intrusion, making it suitable for regions exposed to severe weather.
Fall Protection For 2-1/2-inch SSR Batten Seam Panels
The 2-1/2 inch batten seam's structural steel versions fully support SSRA seam-mounted anchors, walkboard adapters, and horizontal lifeline systems without piercing the metal surface.
Steel 2-1/2-inch SSR Batten T-Seams meet the strength requirements needed for the complete SSRA lineup of non-penetrating anchors. The seam height and material thickness provide the SSRA1 with a broad, stable clamping surface, enabling it to create a dependable tie-off point without drilling through the panel or interfering with the floating-clip design.
The SSRA1 Standing Seam Roof Anchor attaches with low-torque set screws, creating a fall-arrest point that preserves the integrity of the tall batten seam. This device is an ideal choice for single-user tie-off when completing installation, maintenance, or repair tasks.
For crews who need secure footing across long roof runs, the SSRA2 Adjustable Roof Jack Adapter mounts onto two SSRA1 anchors and supports standard 10-foot walkboards. Its adjustable-height legs align with the 2-1/2 inch rib height, creating a comfortable working platform that improves productivity and reduces fatigue.
When horizontal mobility becomes essential, the SSRA3 Anchor Plate joins two SSRA1 anchors together and forms a rigid base for lifeline systems. It works seamlessly with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, which includes two SSRA3 plates, four SSRA1 seam anchors, and the Malta Dynamics HLL3001 lifeline assembly. This assembly gives two workers a continuous tie-off while moving along the roofline.
For buildings that require routine service access, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit offers a long-term solution that stays in place year-round. It spreads loads evenly across multiple SSRA1 anchors and avoids roof penetrations that could compromise the weather-tight seam.
For aluminum 2-1/2-inch Batten T-Seams, the SSRA devices are not recommended. For slopes between 6:12 and 12:12, the preferred option is the Ridge Pro Steep Assist Anchor, which hooks over the ridge and provides a non-penetrating, secure connection point before workers ever step onto the metal surface.
Twin-Fold Mechanical Panels

Fabral's Twin-Fold mechanically-seamed standing seam panel offers precision engineering, strong structural performance, and a wide range of sizes for advanced metal roofing projects.
The Fabral Twin-Fold Mechanical Panel provides a refined, low-profile standing seam system for roofing projects that demand accuracy and durability. Contractors often select this panel for roofs that require tapering because it allows precise alignment across changing geometries. The Twin-Fold is produced in 22-gauge steel, 24-gauge steel, or .032 aluminum, giving designers flexibility in structural strength and weight. See the Roof Anchor Compatibility Chart for Fabral Twin-Fold Mechanical 22 gauge and 24 gauge Standing Seam Panels.
Fabral offers the Twin-Fold in 12-, 16-, and 18-inch widths, with a minimum slope requirement of 3:12. This supports a wide range of residential, commercial, and industrial applications. Roof lengths range from 6 to 47 feet, helping reduce end laps and improve weather performance. The mechanically seamed joinery withstands wind, rain, and thermal expansion while maintaining a crisp architectural appearance.
Fall Protection For Twin-Fold Panels
The steel versions of Fabral's Twin-Fold panel support non-penetrating SSRA anchors, walkboard adapters, and lifeline systems that protect the seam profile and maintain OSHA compliance.
Working safely on 22 and 24-gauge Twin-Fold panels requires fall protection equipment that maintains the panel's mechanical seam and factory finish. The SSRA1 Standing Seam Roof Anchor clamps securely to the Twin-Fold seam and forms a fall arrest connection that protects the roof surface. The low-torque connection method allows the seam to remain intact and able to expand during temperature changes.
When roofers need a solid walking surface, the SSRA2 Adjustable Roof Jack Adapters attach onto SSRA1 anchors and carry standard 10-foot walkboards. This adapter adjusts to different seam heights and creates a stable working surface for tasks such as fastening panels, trimming edges, or installing ridge components.
For larger Twin-Fold projects that require increased movement across larger roof areas, the SSRA3 Anchor Plate links two SSRA1 anchors. It forms a rigid mounting point for lifeline systems. It works with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, which includes the SSRA3 plates, SSRA1 anchors, and the Malta Dynamics HLL3001 rope lifeline. This complete kit supports two workers and keeps them tied off while they move along the roof.
When a facility requires long-term or recurring rooftop access, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit provides a fixed solution that stays in place year after year. It distributes loads across multiple SSRA1 anchors while preserving mechanical seams without drilling.
For aluminum Twin-Fold panels or roofs with slopes between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor is the preferred option. It hooks over the ridge and provides a connection point before workers step onto the metal surface. The Ridge Pro keeps workers tied off from the ladder to the ridge and back again, without altering the roof.
Twin-Fold panels can be tapered, but a fall protection expert should evaluate any tapered or curved installation before selecting anchorage equipment. A trained professional can determine the safest non-penetrating method for the roof's design.
Stand N Seam Mechanical Panels

Fabral's Stand N Seam mechanically-seamed roofing system delivers unmatched wind uplift strength, structural durability, and high performance for commercial and industrial metal roof applications.
The Fabral Stand N Seam Panel is one of the strongest structural standing seam metal roofing systems in the industry. This panel uses a double-locked mechanical seam that creates exceptional weather resistance and remarkable wind uplift ratings. The system relies on a single-piece clip that allows continuous thermal movement, helping the roof accommodate seasonal expansion and contraction without stressing the seams. See the Roof Anchor Compatibility Chart for Fabral Stand N Seam Mechanical 22 gauge and 24 gauge Standing Seam Panels.
Fabral manufactures Stand N Seam panels in 12-inch and 16-inch widths, with a seam height of 2 -1/2 inches. That taller seam profile improves drainage performance and allows installers to use minimum slopes as low as 1/2:12. Stand N Seam is available in 22-gauge steel, 24-gauge steel, aluminum, and copper, giving builders flexibility across a wide range of project requirements.
Engineers rely on this panel for high-wind zones, industrial facilities, and large commercial structures where long-term strength and roof longevity are critical.
Fall Protection For Stand N Seam Panels
Steel Stand N Seam roofs support non-penetrating SSRA anchors and lifeline systems that protect the panel seams, maintain weather performance, and ensure OSHA-compliant tie-off points.
Working safely on Fabral Stand N Seam panels requires fall protection systems that protect the roof's tall mechanical seam and structural design. For 22-gauge and 24-gauge steel panels, the SSRA1 Standing Seam Roof Anchor delivers a dependable tie-off solution. It grips the tall seam with twelve stainless-steel set screws, allowing the roof to move normally with temperature changes.
For roofers who need stable footing on steep roofs, the SSRA2 Adjustable Roof Jack Adapters attach to two SSRA1 anchors and support 10-foot walkboards. This assembly provides workers with a level working surface during panel installation, inspections, or repairs.
When a project requires maximum worker mobility, the SSRA3 Anchor Plate serves as an anchor point for horizontal lifeline systems. It links two SSRA1 anchors into a single rigid assembly that supports temporary lifelines. The SSRA HLL 100-foot Temporary Horizontal Lifeline Kit includes SSRA3 plates, SSRA1 anchors, and the Malta Dynamics HLL3001 rope system. It supports two workers who need to stay tied off while moving along the length of a Stand N Seam roof.
For long-term or frequently accessed roofs, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit provides a durable, ready-to-use system that remains installed year-round. It distributes loads across multiple anchors and helps maintain the roof's weather performance without any surface penetrations.
Because SSRA1 anchors require steel at least 24 gauge, they are not compatible with aluminum or copper Stand N Seam panels. For those substrates, or when the roof pitch falls between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor is the recommended system. It hooks securely over the highest point of the roof. It allows workers to clip in before they ever step onto the metal surface. This device keeps them tied off from ladder to ridge and back again without affecting the seam profile.
Powerseam Mechanical Panels

Fabral Powerseam panels deliver low-slope performance for architectural and commercial standing-seam roof systems.
The Fabral Powerseam Panel is one of the company's most versatile mechanically-seamed roof systems. Powerseam panels come in 12-inch, 16-inch, and 18-inch coverage widths with a 2-inch seam height, providing installers with a tall vertical profile that improves water drainage and weather resistance. These panels perform well on slopes as low as 1:12 pitch and can be single-locked or double-locked, depending on project requirements. See the Roof Anchor Compatibility Chart for Fabral Powerseam Mechanical 22 gauge and 24 gauge Standing Seam Panels.
A defining feature of the Powerseam system is its ability to be curved in the field, providing designers with broad flexibility for architectural accents, barrel roofs, and radius structures. Contractors can order the panels in 22-gauge steel, 24-gauge steel, or aluminum, making the system suitable for both structural and architectural applications.
Fall Protection For Powerseam Panels
Working safely on Fabral Powerseam roofs requires fall protection systems that protect the mechanical seam and the continuous weather-tight membrane created during seaming.
For non-curved, 22-gauge and 24-gauge steel Powerseam panels, the SSRA1 Standing Seam Roof Anchor serves as the seam anchor. It grips the tall seam using non-penetrating set screws. This attachment method preserves the mechanical seam and maintains full weather performance.
For crews who need walkboards, the SSRA2 Adjustable Roof Jack Adapters attach to a pair of SSRA1 anchors. This assembly creates a stable platform for ten-foot walkboards. The adjustable legs allow the system to easily adapt to the taller 2-inch seam profile, providing installers with a comfortable working position during long installation runs.
Larger projects often require more worker mobility, and that is where the SSRA3 Anchor Plate becomes essential. It connects two SSRA1 anchors into one rigid assembly that supports temporary lifelines. When used with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, workers can move along the length of the roof while staying tied off at all times. This kit includes SSRA3 plates, SSRA1 anchors, and the Malta Dynamics HLL3001 lifeline, creating a complete fall restraint and fall arrest system for two workers.
For buildings that receive frequent service or annual inspections, the Super Anchor 120-foot Permanent Horizontal Lifeline Kit offers a ready-to-use long-term anchor system. Once installed, it provides repeat access without the headaches of installing anchors. It distributes loads across multiple anchor points to maintain the Powerseam roof's structural and weather integrity.
Because Powerseam panels can be curved, a straight seam clamp is not suitable for radius installations. A trained fall protection specialist must inspect any curved project before determining which anchorage method is safe and permissible.
Aluminum Powerseam panels cannot support SSRA seam anchors due to their softer metal and lower seam strength. For these projects, and for roof slopes between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor is the preferred non-penetrating method. It hooks over the ridge and allows workers to clip in before stepping onto the roof, maintaining a full tie-off from the ladder to the ridge and back again.
Powerseam II Mechanical Panels

Fabral Powerseam II panels provide structural strength, seam-height versatility, and optional curving, appealing to architects and contractors seeking adaptable standing-seam metal roof systems.
The Fabral Powerseam II system builds on the reputation of the original Powerseam design by offering the same dependable performance with refinements that suit a broad range of architectural and commercial projects. Panels are available in 12-, 16-, and 18-inch coverage widths, with a minimum slope of 1:12, making the system suitable for low-slope applications where reliable drainage is critical. See the Roof Anchor Compatibility Chart for Fabral Powerseam II Mechanical 22 gauge and 24 gauge Standing Seam Panels.
Powerseam II is available in 22-gauge and 24-gauge steel, as well as aluminum, allowing builders to specify the material that best meets the project's structural demands. Like the original series, Powerseam II panels can be curved in the field, enabling distinctive shapes that give architects greater design freedom for radius roofs, barrel vaults, and specialty structures.
Fall Protection For Powerseam II Panels
Non-penetrating anchors that clamp securely to straight seams provide the safest, most roof-friendly fall protection solution for Fabral Powerseam II applications.
Working on Powerseam II requires a fall protection system that preserves the tall mechanical seams created during field seaming. For non-curved, 22-gauge and 24-gauge steel panels, the SSRA1 Standing Seam Roof Anchor provides the first point of protection. It grips the seam gently yet firmly with stainless-steel set screws that prevent seam distortion while creating a dependable anchor point for personal fall arrest gear.
When crews need a walking surface on steep roof areas, the SSRA2 Adjustable Roof Jack Adapters mount to a pair of SSRA1 anchors and support 10-foot walkboards. Its adjustable design fits easily over the taller seam profile of the Powerseam II system, giving installers a stable platform for hands-on work.
For extended access areas, the SSRA3 Anchor Plate becomes essential. It links two SSRA1 anchors into one rigid assembly that supports temporary lifeline systems. When paired with the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, workers can move freely across long Powerseam II roof sections while staying tied off at every stage of the job. This complete kit combines SSRA1 anchors, SSRA3 plates, and a Malta Dynamics lifeline to protect two workers without requiring any roof fasteners.
On busy facilities or sites that require frequent access, building owners often choose the Super Anchor 120-foot Permanent Horizontal Lifeline Kit. This long-term system remains mounted for future service work. It distributes loads evenly across multiple attachment points, all while keeping the Powerseam II roof weather-tight.
Because Powerseam II panels can be curved, crews need to take extra precautions. A trained fall protection specialist should evaluate curved roof projects before selecting an anchorage method. Curved standing seam roofs require specialized solutions.
Aluminum versions of the Powerseam II panels do not support seam-mounted anchorage. For these projects, and for any Powerseam II roof with a pitch between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor is the preferred non-penetrating option. It hooks over the ridge and allows the worker to connect their lifeline before stepping onto the roof surface, keeping them tied off from start to finish.
Thin Seam Snaplock Panels

Fabral Thin Seam panels offer design flexibility, tall snaplock ribs, and multiple substrate options that suit architectural, commercial, and specialty roofing applications.
The Fabral Thin Seam system is a versatile snaplock standing seam roof panel designed for builders who need a clean architectural look combined with dependable structural performance. The 1-3/4-inch rib height provides strong visual definition while allowing the panel to perform on low-slope roofs with a 1:12 pitch. Installers can choose from 12-, 16-, or 18-inch widths, giving the system broad appeal for modern residential projects, large commercial roofs, and custom architectural work. See the Roof Anchor Compatibility Chart for Fabral Thin Seam Snaplock 22 gauge and 24 gauge Standing Seam Panels.
The Thin Seam can be produced in 22-gauge or 24-gauge steel, or in aluminum or copper, depending on the project's aesthetic or structural needs. It installs over solid decking or open framing, and the option for panel tapering makes it a strong contender for roofs with unique geometry. Its tall snaplock ribs create a secure connection without mechanical seaming, providing a fast, straightforward installation process across a range of building types.
Fall Protection For Thin Seam Panels
Safe work on Fabral Thin Seam panels requires non-penetrating anchor systems that match the seam shape and preserve the roof's long-term performance.
For non-tapered Thin Seam steel panels in 22-gauge and 24-gauge, a complete fall protection setup begins with the SSRA1 Standing Seam Roof Anchor. It grips the tall snaplock rib with non-penetrating set screws that protect the seam profile while creating a reliable connection point for personal fall arrest equipment. The SSRA1 keeps the roof surface untouched, which maintains the weather-tight seal and the panel's factory finish.
When crews need a stable work surface for steep roofs, the SSRA2 Adjustable Roof Jack Adapters mount on two SSRA1 anchors and support ten-foot walkboards. This adapter adjusts to accommodate the taller rib shape of the Thin Seam system, providing workers with a balanced platform for hands-on tasks that require both reach and precision.
For larger roof areas, the SSRA3 Anchor Plate links two SSRA1 anchors into an anchoring assembly that can serve as the foundation for temporary horizontal lifelines. Once the SSRA3 plates are in place, contractors can deploy the SSRA HLL 100-foot Temporary Horizontal Lifeline Kit, which protects two workers as they travel the roofline without disconnecting. This system combines SSRA1 clamps, SSRA3 plates, and the Malta Dynamics lifeline for complete coverage on steel Thin Seam installations.
Those managing facilities with frequent rooftop access often prefer the Super Anchor 120-foot Permanent Horizontal Lifeline Kit. It stays mounted after the initial installation, minimizing future setup time and giving maintenance crews a dependable tie-off point whenever they return to the roof.
For aluminum- and copper-versions of the Thin Seam panels, SSRA clamps are not compatible due to the panels' softer base material. For these roofs, especially those with slopes between 6:12 and 12:12 pitch, the Ridge Pro Steep Assist Anchor provides the safest non-penetrating solution. It hooks over the ridge and lets the worker attach their line before stepping onto the roof, maintaining full tie off from start to finish.
For tapered or curved Thin Seam panels, a fall protection specialist should inspect the roof before selecting any equipment. Specialty seams behave differently under load, and choosing the proper non-penetrating anchor ensures both worker safety and roof protection.
Slim Seam Snaplock Panels

Fabral Slim Seam panels combine a tall architectural rib, snaplock efficiency, and structural strength for low-slope residential and commercial metal roofs.
The Fabral Slim Seam panel features a 1-1/2-inch snaplock seam that performs exceptionally well on low-slope roofs with a 1:12 pitch. This structural snaplock rib fastens with one-piece stainless steel clips that allow the panel to float as temperatures change, protecting the finish and keeping the system weather-tight. Slim Seam panels are available in 12-inch and 16-inch widths. They are produced from 24-gauge steel, offering dependable strength for both new construction and retrofit work. See the Roof Anchor Compatibility Chart for Fabral Slim Seam Snaplock 22 gauge and 24 gauge Standing Seam Panels.
One defining advantage of the Slim Seam line is its ability to curve to meet the needs of custom architectural designs. Because curved seams carry loads differently, crews must avoid using seam-mounted fall protection devices on any radius panel. A trained safety expert evaluates those installations before work begins to select the safest non-penetrating method.
Fall Protection For Slim Seam Snaplock Panels
Safe work on Fabral Slim Seam roofing requires non-penetrating anchor systems that match the tall snaplock rib while preserving panel movement and finish quality.
For non-curved, 22-gauge and 24-gauge steel Slim Seam panels, crews can use the full range of Standing Seam Roof Anchor (SSRA) equipment. The SSRA1 anchor grips the seam with non-penetrating set screws. This feature creates a dependable connection point for a single worker without penetrating the seams.
Workers who need a level work platform for steep roofs can mount the SSRA2 Adjustable Roof Jack Adapters on a pair of SSRA1 anchors. The adapters support ten-foot walkboards and adjust to match the taller Slim Seam rib profile, giving roofers a comfortable work surface during long installation runs or detail work along ridges and transitions.
For extended travel along the roofline, the SSRA3 Anchor Plate joins two SSRA1 anchors into a rigid unit that serves as a base for temporary lifelines. The SSRA HLL 100-foot Temporary Horizontal Lifeline Kit includes two SSRA3 plates, four SSRA1 anchors, and a Malta Dynamics 100-foot lifeline system. This combination lets two workers move freely while remaining securely tied off from eave to eave.
Facilities that require routine roof access can rely on the Super Anchor 120-foot Permanent Horizontal Lifeline Kit. This HLL system distributes load across multiple seam locations. It eliminates setup time for future inspections or service visits, providing building owners and maintenance crews with a consistent, OSHA-compliant tie-off solution.
Because aluminum and copper Slim Seam panels are a softer material, crews should avoid using seam clamps on these substrates. For these roofs, especially when the slope falls between 6:12 and 12:12, the Ridge Pro Steep Assist Anchor provides the best non-penetrating alternative. It hooks over the peak and lets the worker connect their line before stepping onto the roof, offering continuous tie off from ladder to ridge and back again.
For curved Slim Seam panels, a fall protection professional assesses the roof in person before selecting the proper anchor method to ensure complete safety and long-term roof protection.
IP Seam 3 Panels

Fabral IP Seam 3 panels use a tall trapezoidal rib and structural steel construction to deliver dependable performance on low-slope commercial metal roofs.
The Fabral IP Seam 3 panel is a rugged, structural roofing option that relies on a 3-inch tall trapezoidal rib to shed water quickly. Because this seam profile efficiently channels runoff, the system can be used on roofs with a minimum 1:12 pitch, giving designers more flexibility on industrial or commercial projects. Fabral manufactures the IP Seam 3 in 22-gauge and 24-gauge steel, which provides the panel with a substantial load capacity and dependable wind uplift resistance. It is a smart fit for warehouses, manufacturing facilities, distribution centers, and large commercial footprints that demand long-lasting performance. See the Roof Anchor Compatibility Chart for Fabral IP Seam 3 22 gauge and 24 gauge Standing Seam Panels.
Fall Protection For IP Seam 3 Panels
Non-penetrating anchors protect the tall 3-inch rib while delivering safe, OSHA-compliant tie-off options for Fabral IP Seam 3 roofing.
Steel IP Seam 3 roofs pair well with SSRA fall protection systems because the tall trapezoidal ribs provide the seam clamps with a broad, solid contact point. The SSRA1 anchor grips the seam with six pairs of opposing set screws, creating a stable single-user tie-off point that avoids seam penetrations.
When a roofer requires walkboards for steep roofs, crews can set a pair of SSRA2 Adjustable Roof Jack Adapters on top of SSRA1 anchors. This arrangement supports ten-foot walkboards and creates a level work platform to help installers and maintenance crews move materials and perform repairs.
For projects that require maximum worker mobility, the SSRA3 Anchor Plate links two SSRA1 anchors into anchor points for horizontal lifeline systems. The SSRA HLL 100-foot Temporary Horizontal Lifeline Kit includes two SSRA3 plates, four SSRA1 anchors, and a Malta Dynamics lifeline system. This setup keeps two workers tied off at all times while they travel along long spans of IP Seam 3 roof.
Facilities with regular rooftop maintenance can upgrade to the Super Anchor 120-foot Permanent Horizontal Lifeline Kit, which remains in place year-round. This permanent solution offers continuous tie-off, eliminating the need for repeated setup.
When manufacturers produce the IP Seam 3 profile in aluminum, the softer base metal is not compatible with seam-mounted anchors. Crews working on aluminum versions, especially when slopes fall between 6:12 and 12:12, should use the Ridge Pro Steep Assist Anchor. It hooks over the ridge and lets the worker connect their line before stepping onto the roof, keeping them tied off from ladder to ridge and back again.
IP Snap 3 Panels

Fabral IP Snap 3 panels combine tall trapezoidal ribs with structural steel construction to deliver dependable performance on low-slope metal roofing projects.
The Fabral IP Snap 3 panel builds on the strengths of the IP Seam 3 series. It uses a snaplock installation that streamlines field work while maintaining its structural profile. Fabral forms these panels in 22- and 24-gauge steel, and each panel uses a 3-inch-tall trapezoidal rib that sheds water efficiently on low-slope roofs with pitches as low as 1/2:12. The panels provide full 24 inches of coverage. Fabral offers lengths from 6 to 47 feet so that contractors can handle compact projects, long commercial runs, and everything in between. See the Roof Anchor Compatibility Chart for Fabral IP Snap 3 22 gauge and 24 gauge Standing Seam Panels.
Fall Protection for IP Snap 3 Panels
Non-penetrating anchors deliver stable tie-off points on the structural ribs of the Fabral IP Snap 3 panel without altering the seam profile.
The steel versions of the IP Snap 3 panel accept the full suite of SSRA fall protection solutions to create dependable anchorage without drilling through the roof surface. The SSRA1 Standing Seam Roof Anchor locks to the seam with non-penetrating set screws, producing a solid personal fall arrest point that does not penetrate the steel.
When work requires a stable footing across steep panel runs, the SSRA2 Adjustable Roof Jack Adapters attach to two SSRA1 anchors and support ten-foot walkboards. This adapter creates a level work platform that reduces worker fatigue and keeps material handling steady on steep IP Snap 3 roof areas.
For tasks that involve larger roof areas, the SSRA3 Anchor Plate joins two SSRA1 anchors into a rigid connection point for lifeline systems. The SSRA HLL 100-foot Temporary Horizontal Lifeline Kit includes SSRA3 plates, four SSRA1 anchors, and a 100-foot Malta Dynamics lifeline assembly, so two workers remain tied off while traveling along the full length of the roof.
Facilities that see recurring rooftop inspections or routine equipment service benefit from the Super Anchor 120-foot Permanent Horizontal Lifeline Kit. This permanent system distributes loads across multiple seams and remains ready for use year-round without repeated setup.
For IP Snap 3 roofs installed in aluminum or with a slope between 6:12 and 12:12, seam clamps are not compatible. The Ridge Pro Steep Assist Anchor is the safest non-penetrating option because it hooks over the ridge and provides a tie-off point the moment they reach the peak. This approach preserves the panel finish and keeps crews connected throughout every stage of steep slope work.
Snap-On Batten Panels

Fabral Snap-On Batten panels feature a raised batten cap profile that creates a distinctive architectural look while allowing thermal expansion across long roof runs.
The Fabral Snap-On Batten panel series features an architectural profile with a 1-7/8-inch seam height and a concealed clip system that allows unrestricted panel movement. Available in 12, 16, 18, and 20-inch widths, this panel fits a wide range of design requirements across commercial and residential structures. Because the batten cap sits over the panel edges rather than forming a conventional standing seam, the system creates bold shadow lines and a pronounced vertical rhythm that many designers prefer. See the Roof Anchor Compatibility Chart for Fabral Snap-On Batten Standing Seam Panels.
Fabral manufactures the Snap-On Batten panel in aluminum and 22- or 24-gauge steel, with a minimum slope requirement of 3:12. The concealed clip design reduces stress on the fasteners, improves long-term weather resistance, and maintains the clean architectural appearance that defines batten cap roofing.
Fall Protection For Snap-On Batten Panels
Batten cap seams require ridge-based fall protection because the profile cannot support clamp-style anchorage used on traditional standing seam systems.
The raised cap on the Snap-On Batten panel prevents the use of seam-mounted anchors, such as the SSRA1 Standing Seam Roof Anchor, SSRA2 Adjustable Roof Jack Adapter, and SSRA3 Anchor Plate.
For this panel style, the best non-penetrating option remains the Ridge Pro Steep Assist Anchor for slopes between 6:12 and 12:12. The Ridge Pro hooks securely over the ridge and lets the worker clip in before stepping onto the metal surface. This approach protects the roofing system, keeps workers connected during ascent and descent, and meets OSHA requirements for safe access.
Snap-On Seam Panels

A batten strip profile that requires a ridge-based anchor solution for workers.
This panel uses a two-piece snaplock configuration where the panel attaches first, followed by a separate batten cap that covers the joint. Since the batten cap is not structural, seam anchors such as the SSRA1 are incompatible.
Fabral offers this panel in steel or aluminum with widths from 12 to 20 inches and seam heights of 1 inch or 1-3/4-inches. The profile works well in architectural settings where visual style matters as much as weather protection and long-term durability. Minimum slope starts at 3:12, and installers can taper or curve the panel when the project calls for radius work on complex roof geometry. See the Roof Anchor Compatibility Chart for Fabral Snap-On Seam Standing Seam Panels.
Fall Protection For Fabral Snap-On Seam Panels
Only ridge-based fall protection is suitable since this profile uses a snap-over batten cap.
The Ridge Pro Steep Assist sits over the ridge and gives crews a secure place to connect on 6:12 to 12:12 roofs. The tool hooks over the peak using a long extension pole so the worker stays tied off from the ladder, at the ridge, and all the way back down. This method protects the watertight seal and keeps the decorative snap cap free from clamp pressure or seam distortion.
Snap-On Seam panels are popular on custom building projects and radius work, and curved roof sections introduce additional planning steps. A qualified safety professional should review any curved or tapered version of this panel since anchor locations, load direction, and seam orientation can vary across the roof.
Ultra Loc Panels

Fabral Ultra Loc panels deliver a clean, concealed-fastener look with snaplock simplicity, ideal for residential and light commercial roofing projects.
The Fabral Ultra Loc panel appeals to installers who want a standing seam profile that balances pleasing aesthetics with fast installation. The concealed fastening system hides every screw beneath the panel, creating a smooth appearance that meets the expectations of modern architectural design. With a 16-inch coverage and a 1-inch rib height, the panel locks neatly into place. It forms consistent shadow lines that look uniform across long roof runs. See the Roof Anchor Compatibility Chart for Fabral Ultra Loc Standing Seam Panels.
Ultra Loc installs easily over solid decking and can also be placed on certain existing roofs, giving contractors flexibility during renovations or residential upgrades. This panel performs best on slopes of 3:12 or greater, and Fabral offers it in 26-gauge steel with custom lengths up to 40 feet. Homeowners and builders often choose Ultra Loc for its blend of affordability and practical performance, as it installs well on homes, barns, shops, and light commercial buildings without the complexity of mechanical seaming.
Fall Protection For Ultra Loc Panels
The Fabral Ultra Loc seam shape supports non-penetrating Ridge Pro anchorage solutions for safe work on slopes from 6:12 to 12:12.
The seam shape of the Ultra Loc panel prevents the use of seam-mounted anchors such as the SSRA1, SSRA2, or SSRA3. Instead, crews should use the Ridge Pro Steep Assist Anchor when working on slopes from 6:12 to 12:12. The Ridge Pro sits over the roof peak and provides a secure connection for a lifeline before the worker ever transitions from the ladder to the metal surface.
This approach preserves the concealed-fastener design of the Ultra Loc panel while providing installers and maintenance crews with a safe, reliable tie-off method. For any unusually shaped roofs or projects involving additions or roof transitions, a fall protection professional should evaluate the site to verify that the chosen anchor arrangement matches OSHA requirements and the panel's structural limits.
Standing Seam Metal Roof Anchor Panel Compatibility Chart For Fabral 22 Ga. Panels
| 2-1/2-inch SSR 18-22 Ga. | Twin-Fold 22 Ga. | Stand-N-Seam 22 Ga. | Powerseam 22 Ga. | Powerseam II 22 Ga. | Thin_Seam 22 Ga. | Slim_Seam 22 Ga. | IP Seam 3 22 Ga. | IP_Snap_3 22 Ga. | |
|---|---|---|---|---|---|---|---|---|---|
SSRA 1![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES |
SSRA1 Nylon Tip![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES |
SSRA2 Roof Jack![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES |
SSRA3 Anchor Plate![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES |
The Ridge Pro![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES |
Standing Seam Metal Roof Anchor Panel Compatibility Chart For Fabral 24 Ga. Panels
| 2-1/2-inch SSR 24 Ga. | Twin-Fold 24 Ga. | Stand-N-Seam 24 Ga. | Powerseam 24 Ga. | Powerseam II 24 Ga. | Thin_Seam 24 Ga. | Slim_Seam 24 Ga. | IP Seam 3 24 Ga. | IP_Snap_3 24 Ga. | 1-1/2-inch SSR 24 ga. | |
|---|---|---|---|---|---|---|---|---|---|---|
SSRA 1![]() |
NO | NO | NO | NO | NO | NO | NO | NO | NO | NO |
SSRA1 Nylon Tip![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES | YES |
SSRA2 Roof Jack![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES | YES |
SSRA3 Anchor Plate![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES | YES |
The Ridge Pro![]() |
YES | YES | YES | YES | YES | YES | YES | YES | YES | YES |
Standing Seam Metal Roof Anchor Panel Compatibility Chart For Fabral SSR Panels
| Horizon S | Horizon S100 | Horizon 16 | Snap-On Batten | Ultra Loc | 1-1/2-inch SSR 150 24 Ga. |
Snap-On Seam | |
|---|---|---|---|---|---|---|---|
SSRA 1![]() |
NO | NO | NO | NO | NO | NO | NO |
SSRA1 Nylon Tip![]() |
NO | NO | NO | NO | NO | YES | NO |
SSRA2 Roof Jack![]() |
NO | NO | NO | NO | NO | YES | NO |
SSRA3 Anchor Plate![]() |
NO | NO | NO | NO | NO | YES | NO |
The Ridge Pro![]() |
YES | YES | YES | YES | YES | YES | YES |
Contact Us for Expert Standing Seam Fall Protection Advice
For expert guidance on standing seam roof anchors, lifeline kits, and fall protection systems that protect both your crew and your panels, contact us today at 863-703-4522 or visit www.StandingSeamRoofAnchor.com. Our safety specialists can help you match the right non-penetrating anchor to your specific roof profile and slope. Let's make your next metal roofing project safe, compliant, and built to last.
For continued learning, download OSHA's 48-page Fall Protection Manual and our free Anchor Inspection Form once you've selected the ideal anchors for your roof system. Together, we'll help you stay ahead of OSHA standards while preserving your roof's weather-tight seal.
Safety Tips For Standing Seam Roofs
Equip Workers with High-Quality Safety Gear
Fabral roofs perform best when crews rely on gear that has been inspected, fitted, and matched to the job. Quality fall protection equipment determines whether workers can move confidently on Fabral standing seam systems, such as Horizon S, Ultra Loc, Stand N Seam, and Powerseam panels. Crews who use well-fitted harnesses, Malta Dynamics SRLs, and connectors that pair cleanly with non-penetrating anchor systems stay compliant with OSHA rules and avoid gear failures that lead to costly injuries.
Use Specialized Anchor Systems for Standing Seam Roofs
Fabral standing seam panels demand anchor systems engineered for their seam shapes, coated steel surfaces, and the concealed-fastener designs for which Fabral is known. Non-penetrating anchors, such as the SSRA1 clamp, attach to the seam without drilling or damaging Kynar finishes. When crews add SSRA2 Adjustable Roof Jack Adapters for walkboard support or SSRA3 Anchor Plates for temporary lifelines, the setup forms a complete safety system suited for Fabral products such as Thin Seam, IP Seam 3, or Powerseam. Safety directors should avoid clamps that require excessive torque, as high torque can crush seams and void warranty protection on Fabral panels.
Install Permanent Roof Anchor Systems
Buildings that use Fabral roof systems for commercial operations often require routine rooftop access for HVAC systems, solar arrays, and annual inspections. The Super Anchor 120-foot Permanent Horizontal Lifeline Kit solves this problem by giving maintenance crews a ready-to-use tie-off system that stays in place for decades. Permanent lifeline setups reduce repeated roof traffic during anchor installation and help protect the finish of Fabral 22- and 24-gauge panels, which must remain weather-tight for warranty coverage.
Prioritize Ladder Safety Training
Many injuries happen before anyone touches a Fabral panel. The four-to-one rule, stable footing, and three points of contact help prevent ladder kickouts that send workers onto metal decks or ground surfaces. Regular ladder training gives roofing crews confidence during access and reduces mishaps at the start of each work session.
Develop OSHA Compliant Safety Plans
Fabral roofing projects move smoothly when everyone follows a written safety plan that maps out tie-off points, lifeline paths, and rescue procedures. Clear planning matters whether the crew installs Fabral Twin Fold mechanical panels or Ultra Loc snaplock profiles on a residential reroof. OSHA-compliant planning clarifies who monitors fall zones, who conducts inspections, and how workers communicate while moving across panels. A consistent plan limits mistakes and increases safety on complex Fabral roofs.
Encourage the Use of Trauma Straps
Suspension trauma can turn a fall arrest into a medical emergency. Trauma straps attach directly to a worker's harness and allow them to shift weight after a fall while hanging from an SSRA1 seam clamp or a Ridge Pro Steep Assist anchor on a steep Fabral roof. These small straps provide relief that maintains circulation while the rescue team responds. Every roofer working on Fabral standing seam profiles should carry trauma straps because they offer inexpensive, life-saving protection.
Set Up Protective Guardrail Barriers for Work Zones
Guardrails play a crucial role during Fabral panel installation and maintenance. When crews install guardrails near eaves, skylights, or transitions between roof levels, they reduce the number of areas where a misstep can turn into a fall. These barriers complement seam-mounted anchors by limiting exposure to fall zones while workers move materials across the roof.
Promote a Culture of Safety
Crews that install Fabral metal roofing systems succeed when safety becomes a habit rather than a reaction. A quick morning huddle keeps everyone alert to hazards. Workers who speak up about concerns, share tips, and watch out for one another reduce injury risk and improve job-site morale. A strong safety culture keeps crews using anchors, lifelines, and walk boards correctly every time they step onto a metal roof.
Ensure Proper Footwear for Stability
Workers need roofing boots with firm ankle support and soles that grip painted standing seam ribs. Reliable footwear keeps workers balanced and focused on their task rather than on their footing.
Consult Experts for Curved Metal Panels
Curved Fabral panels, such as custom radius Powerseam or tapered Twin Fold installations, require special attention before attaching fall protection anchors. The curvature of the seam can affect clamp attachment and may not support a traditional SSRA system. A fall protection specialist should inspect curved or tapered Fabral roofs to verify what type of non-penetrating anchor or lifeline setup meets OSHA load requirements while respecting the unique panel shape.
Disclaimer
The views, recommendations, and information presented in this blog are solely those of the author and do not necessarily reflect the opinions or positions of the featured panel manufacturer, its brands, subsidiaries, or parent companies. Customers are strongly encouraged to contact the roof panel manufacturer directly for inquiries regarding fall protection compatibility with their products and to address any potential warranty issues that may arise after installing our products.