FallTech 7431 Twin-D Permanent Roof Anchor for Wood
The FallTech 7431 Twin-D Permanent Roof Anchor installs permanently on a wood roof and provides two D-rings, so it can serve two tie-off points or pass a horizontal lifeline through for continuous protection. It stays with the building for ongoing access.
It is certified to ANSI Z359.1-2007, rated to a 5,000 lb anchorage requirement, for one worker up to 310 lb (ANSI) or 425 lb (OSHA).

Who Needs This Product
This product is a permanent twin-D roof anchor, the anchorage component of a personal fall arrest system for wood roofs. Builders install it to give a permanent tie-off point with two D-rings, useful for a lifeline pass-through or two connections, then a worker connects an SRL or lanyard. You still need a certified full-body harness and a compatible connecting device.
Features
Two D-rings
Serve two tie-off points or pass a horizontal lifeline through.
Permanent installation
Stays with the building for ongoing roof access.
Lifeline capable
The twin D-rings suit a lifeline pass-through for continuous travel.
Wood roof mount
Fastens to sound rafters or trusses per the manual.
Durable steel
Built to last as a permanent anchor.
ANSI Z359.1-2007
Certified for one worker up to 310 lb.
Fasten to sound framing per the manual and flash the install. Drive all required fasteners into solid rafters or trusses and seal the anchor for a weather-tight permanent install. Confirm fall clearance and swing-fall with the Fall Protection Calculator below.
Compliance Standards
ANSI Z359.1-2007
American National Standard for fall arrest components. Rated 5,000 lb (22.2 kN).
OSHA 29 CFR 1926.502
Federal construction fall protection anchorage requirements.
OSHA 29 CFR 1910
General industry personal fall protection requirements.
Rated 5,000 lb (22.2 kN)
Anchorage strength for personal fall arrest.
Typical Applications
How to Install
Follow the FallTech instruction manual. The sequence below is an overview only.
- Inspect. Check the anchor body, connection point, and hardware for damage before each use.
- Prepare the structure. Confirm the mounting surface is sound and rated to support the anchor per the manual.
- Install and secure. Mount the anchor as specified and set all fasteners to the required torque.
- Connect. Attach your SRL or energy-absorbing lanyard to the connection point.
- Check clearance. Confirm fall clearance and swing-fall with the calculator below.
Inspection and Retirement
Inspect before each use, with a documented competent-person inspection at least annually. Remove the anchor from service for any of the conditions below.
- Anchor body and welds: cracks, bending, deformation, or corrosion.
- D-ring or connection point: deformation, sharp edges, cracks, or corrosion.
- Fasteners and hardware: damaged threads, loose or missing fasteners.
- Labels: illegible or missing markings.
Remove the anchor from service immediately after any fall-arrest event, and destroy retired equipment so it cannot return to service.
Technical Specifications
| Type | Twin-D permanent roof anchor for wood |
|---|---|
| Connection | Two D-rings |
| Anchorage classification | ANSI Z359.1-2007 |
| Mounting | Permanent, wood framing |
| Anchorage strength | 5,000 lb (22.2 kN) |
| Capacity (ANSI) | One worker, 130 to 310 lb combined |
| Capacity (OSHA) | One worker, up to 425 lb combined |
| Standards | ANSI Z359.1-2007; OSHA 1926.502 and 1910 |
| Warranty | FallTech 2-year limited warranty against defects in materials and workmanship |
Frequently Asked Questions
FallTech twind Submittals and Documentation
7431 Instruction Manual (PDF)Installation, capacity, and inspection. 7431 Declaration of Conformity (PDF)Certification to ANSI Z359.1-2007 (FallTech test lab). 7431 Spec Sheet (PDF)One-page specifications summary.Related Anchors
- FallTech steel and beam anchors. See the full beam clamp and steel anchor line.
- FallTech fall protection equipment. Harnesses, SRLs, lanyards, and anchors.
Specifying Anchors for Your Crew?
The anchor, the connecting device, and the harness all have to match the structure and the fall clearance below. Confirm your application with us and we will help you choose the right anchor.
Call 863-703-4522 to talk to a fall protection specialist.