New Hampshire Fall Protection Requirements
New Hampshire follows the federal OSHA baseline (no state plan for private employers).
Ask All of Your Fall Protection
Questions Here
New Hampshire fall protection at a glance
| Item | Detail |
|---|---|
| Primary authority | Federal OSHA (U.S. Dept. of Labor) |
| Construction trigger height | 6 ft (29 CFR 1926.501) |
| General industry trigger | 4 ft (29 CFR 1910.28) |
| Report a serious incident | 1-800-321-6742 |
Who regulates fall protection in New Hampshire
| Contact | Detail |
|---|---|
| Agency | Federal OSHA (U.S. Dept. of Labor) |
| Website | Official site |
| Free consultation | WorkWISE NH On-Site Consultation (Keene State College) |
Report a serious injury or death
Report a fatality within 8 hours, and an in-patient hospitalization, amputation, or loss of an eye within 24 hours. Call 911 first in an emergency.
Official page ›New Hampshire requirements beyond the baseline
New Hampshire follows the federal OSHA baseline. New Hampshire follows the federal OSHA baseline (no state plan for private employers).
Equipment and anchorage requirements
Anchorages for personal fall arrest must support 5,000 pounds per attached worker or be engineered with a 2:1 safety factor under 29 CFR 1926.502(d)(15). Guardrails carry the 42 inch, 200 pound rules of 1926.502(b), and equipment is certified to ANSI Z359. Every anchor, harness, and SRL we sell publishes its tested strength on the spec sheet.
Penalties
| Violation type | Maximum |
|---|---|
| Serious | $16,550 |
| Willful or Repeat | $165,514 |
New Hampshire fall protection FAQ
Turn these rules into a printable, site-specific safety plan.
Generate My New Hampshire Safety Plan ›Find the rule for your situation
Every duty in 1926.501, one tap each
Unprotected sides and edges
Any walking or working surface with an edge 6 ft or more above a lower level.
1926.501(b)(1)Low-slope roofs
Roofing work on slopes 4:12 or less, including warning line and safety monitor combos.
1926.501(b)(10)Steep roofs
Any roof steeper than 4:12. Guardrails with toeboards, nets, or personal fall arrest.
1926.501(b)(11)Holes and skylights
Covers, guardrails, or fall arrest over every hole, including every skylight.
1926.501(b)(4)Residential construction
The 6 ft rule for home building, and what a written fall protection plan requires.
1926.501(b)(13)Leading edge work
Building the edge itself: decking, precast, and the controlled access zone rules.
1926.501(b)(2)Personal fall arrest systems
Harnesses, lanyards, SRLs, 5,000 lb anchorages, free fall and clearance limits.
1926.502(d)Guardrail systems
42 inch top rails, midrails, 200 lb strength, flagged lines, and gate rules.
1926.502(b)Warning line systems
Line height, flag spacing, stanchion strength, and the 6 ft / 10 ft setbacks.
1926.502(f)Safety monitoring systems
When a monitor alone is legal, and the five duties the monitor must perform.
1926.502(h)Hole covers
Twice the expected load, secured against displacement, marked HOLE or COVER.
1926.502(i)Training requirements
Who must be trained, by whom, the written certification record, and retraining.
1926.503Hoist areas
Guardrails or fall arrest where materials come up over the edge.
1926.501(b)(3)Excavations, wells, and pits
Guardrails, fences, barricades, or covers at the edge of excavations.
1926.501(b)(7)Fall protection plans
The only legal alternative when conventional protection is infeasible.
1926.502(k)The numbers worth quoting
Cite them anywhere, link this page as the source
Know the rule? Now check your numbers.