1032-PG CRA-PT 12 Inch HLL Pass-Thru Anchor
The Super Anchor 1032-PG is a 12 inch CRA-PT pass-thru anchor post that carries a horizontal lifeline cable through its No. 1091 top as an intermediate anchor. The foam filled, hot dip galvanized 3.0 inch Schedule 40 riser stands on a 16x16x3/8 inch 52-hole base plate, and the anchor is third-party certified with a 5,000 lb ultimate strength.
What is included: the pass-thru anchor post with 4 No. 5010-SM O-rings; HLL cable and rigging hardware are sold separately. Pass-thru tops are HLL intermediate anchors only, never a personal tie-off point. The lifeline cable rides through the top on 4 No. 5010-SM O-rings, so a single run stays continuous between loop top end anchors spaced 20 to 30 ft on center. Because pass-thru anchors serve horizontal lifelines, they must be bolted, field welded, or concrete embedded, never screw attached. Compliant with ANSI Z359.18-17 and OSHA 1926.502, with CSA Z259.15:22 conformity per the 01-2023 manual.

Who Needs This Product
The 1032-PG is for contractors and building owners running CRA horizontal lifelines across commercial roofs. Intermediate pass-thru anchors carry the cable between loop top end anchors so workers travel the full run without disconnecting at each post. Each HLL run supports 2 workers in fall arrest or 4 workers in fall restraint at 310 lb per user including tools, with a spring energy absorber limiting average peak force to 1,200 lb in a 6 ft free fall. Runs are typically 120 ft, with runs up to 130 ft available through third party engineering when pass-thru spacing stays within 30 ft. Every worker on the line wears a full body harness with components meeting current OSHA, ANSI, or CSA standards.
Features
No. 1091 pass-thru top
No. 1091 pass-thru top for 3/8 inch HLL cable with 4 No. 5010-SM O-rings. The cable passes through the top so the run stays continuous across the roof.
4 O-rings included
Each pass-thru top uses 4 No. 5010-SM O-rings, installed on the cable before the clamps during rigging, so the line rides smoothly through the fixture.
Hot dip galvanized steel
ASTM 123 hot dip galvanizing inside and out plus polyurethane foam filling protect the riser, rated for -30 to +130 degrees F.
12 inch standoff
The 12 inch riser lifts the lifeline above gravel, ballast, insulation, and standing water on commercial roofs.
52-hole base plate
The 16x16x3/8 inch plate carries 9/16 inch holes for a minimum of 4 certified 1/2 inch bolts; pass-thru anchors are never screw attached.
Cable clamp slack removal
During rigging, slack is removed by clamping the cable at the pass-thru tops, then released after the turnbuckle is tensioned per the 02-2021 rigging manual.
Technical Specifications
| Model | 1032-PG, CRA-PT 12 inch |
|---|---|
| Pass-Thru Top | No. 1091 pass-thru top for 3/8 inch HLL cable with 4 No. 5010-SM O-rings. |
| Riser | 12 inch height, 3.0 inch O.D. Schedule 40, polyurethane foam filled, ASTM 123 hot dip galvanized |
| Base Plate | 16 x 16 x 3/8 inch with 52 fastener holes; use the 9/16 inch holes with a minimum of 4 certified 1/2 inch bolts |
| O-Rings | 4 No. 5010-SM per pass-thru top, included |
| Ultimate Strength | 5,000 lb minimum in any direction the load is applied |
| Proof Load | Maximum 2,500 lb on site |
| HLL Performance | 2 workers fall arrest or 4 workers fall restraint per run; 310 lb per user including tools |
| Energy Absorber | No. 1065-AS spring energy absorber; 1,200 lb average peak force at 6 ft free fall; 52 inch maximum deployment |
| Run Length | Typically 120 ft; up to 130 ft with third party engineering; intermediate anchors 20 to 30 ft on center |
| Attachment | Bolted, field welded, or concrete embedded only; never screw attached |
| Temperature Rating | -30 to +130 degrees F |
| Product Weight | 37 lb |
| Compliance | ANSI Z359.18-17 Type A/T; OSHA 1926.502 and 1910.140; CSA Z259.15:22 Type A/T; Intertek lab reports; third-party engineering by DH Glabe and Associates |
| UPC | 786158103267 |
Not a tie-off point. The pass-thru top is an HLL intermediate anchor only. Never connect a lanyard, SRL, or lifeline directly to a pass-thru top; personal connections belong on the HLL cable or on loop top anchors. Pass-thru anchors must be bolted, field welded, or concrete embedded because cable vibration and line tension work screws loose, and the supporting structure must hold 5,000 lb or 2 times the intended load per OSHA 1910.140.
Compliance Standards
ANSI Z359.18-17 Type A/T
Anchorage connector compliance verified by Intertek lab reports per the 01-2023 CRA manual.
OSHA 1926.502 / 1910.140
Meets construction anchorage criteria with 5,000 lb structural support requirements.
CSA Z259.15:22 Type A/T
Canadian anchorage connector conformity for cross-border crews.
Factory Engineered HLL Systems
SAS engineered horizontal lifeline runs to 120 ft, with runs up to 130 ft available through third party structural engineering.
Typical Applications
Installation Overview
Full rigging procedures, clamp torque, and tensioning figures are in the CRA HLL Rigging Manual linked below. The essentials:
- Confirm each attachment point supports 5,000 lb or 2 times the intended load, with anchor locations specified by the project architect, engineer, or safety consultant.
- Bolt the base plate with a minimum of 4 certified 1/2 inch grade 8, grade 5, or 18-8 stainless bolts with matching lock nuts, field weld with an E70XX certified welder, or concrete embed in 2,500 PSI minimum concrete.
- Space intermediate pass-thru anchors 20 to 30 ft on center along the run.
- Install 4 No. 5010-SM O-rings on the cable before the cable clamps, then feed the cable through each pass-thru top.
- Remove slack by clamping the cable at the pass-thru tops, rig the B end first, then tension the turnbuckle until the energy absorber gauge closes per the rigging manual.
- Release the pass-thru clamps after tensioning, open the turnbuckle fully before final adjustment, and inspect the completed system before use.
Inspection and Retirement
Inspect before installation and each use, with documented annual inspections. Remove the anchor from service when any of the following apply:
- The riser is bent or deformed.
- Weld cracks are present.
- Rust that does not clean up with cold zinc coating.
- Fasteners are missing; do not use until the installation is corrected.
- The PID label or vent hole plug is missing and cannot be replaced.
- The anchor was subjected to a free fall or the supporting structure is damaged.
Tag anchors removed from service to prevent further use until inspected by a qualified or competent person.
Frequently Asked Questions
1032-PG CRA-PT Pass-Thru Anchor Submittals and Documentation
CRA Instruction/Specification Manual 01-2023 (PDF)Materials, compliance, fastener tables, substrate installations, and inspection criteria. CRA Pass-Thru Anchors Catalog Pages (PDF)2024 catalog specifications for CRA-PT pass-thru anchor models including the 1032-PG. CRA Horizontal Lifeline Rigging Manual (PDF)Pass-thru rigging, O-ring installation, clamp torque, and tensioning procedures for CRA HLL systems. Super Anchor Warranty and Compliance Statement (PDF)Manufacturer warranty terms and compliance statement for Super Anchor Safety products.Compatible and Related Products
- Super Anchor 1032-W CRA 12" Anchor Post. Matching 12 inch loop top post for the HLL end anchors.
- Super Anchor 1031-PG CRA-PT 5 Inch Pass-Thru Anchor. Low profile 5 inch intermediate anchor for bolted installations.
- Super Anchor 1050-G HLL Rigging Kit. Galvanized turnbuckle, energy absorber, and coupler hardware for the run.
- Super Anchor 1031-W CRA 5 Inch Loop Top Anchor Post. Low profile loop top end anchor option.
Designing a Horizontal Lifeline?
Send us the roof plan and we will lay out end anchors, pass-thru intermediates, and rigging hardware for the full system, based on the delivery location.
Call 863-703-4522 to talk to a fall protection specialist.
Super Anchor Safety Manufacturer Warranty
Super Anchor Safety (SAS) warrants to the purchaser that all products are free from defect in material and workmanship at the time of shipment. This warranty is limited to product replacement for a period of one (1) year from the date of installation or use by the owner, provided that this period shall not exceed two (2) years from the date of shipment. This warranty only covers defects in material and workmanship. It does not cover conditions resulting from normal wear, neglect, abuse, or accident. This product warranty does not cover oxidation of zinc, dacromet, or powder coatings used on permanent and temporary anchors that results from connector abrasion unless the coating can be shown to be defective at the time of purchase. This warranty is non-transferable. Any unused defective product will be replaced at no charge by returning the product to Super Anchor Safety or to the distributor the product was purchased from.
Permanent Anchor Warranty
Super Anchor Safety warrants to the purchaser that all anchors sold as a permanent fixture with Hot Dip Galvanizing, Stainless Steel, and Thermo-Plastic finishes are fully warranted against failure due to defects in materials or workmanship for a period of five (5) years from the date of initial installation. SAS does not warranty the installation or flashing system used to waterproof the anchors. The SAS factory warranty is void if the product has been modified or has not been used in accordance with SAS specifications and instructions for that product. Anchors that have been removed from service due to re-roofing or remodel of the structure they were originally attached to must be inspected by an SAS factory representative or a competent person before being reinstalled.
See the Super Anchor Warranty and Compliance Statement (PDF) for the full manufacturer document.