24 Inch CRA Loop Top Anchor Post
The Super Anchor 1042-W is a 24 inch CRA commercial roof anchor post: a No. 1090 cast steel loop top rated at 10,000 lb tensile strength on a polyurethane foam filled, hot dip galvanized 3.0 inch O.D. Schedule 80 riser, on a 16 x 16 x 5/8 inch base plate. Third-party certified with a 5,000 lb minimum ultimate strength in any direction the load is applied to the loop top.
Use it as a single person PPE anchor, a window washing tie-off, or an anchor in CRA horizontal lifelines up to 240 ft. The heavy Schedule 80 riser and 5/8 inch plate suit bolted, embedded, and welded structural installations. Compliant with ANSI Z359.18-17 Type A/T, CSA Z259.15:22, ANSI/IWCA 1-14.1, and OSHA 1926.502 per the 01-2023 CRA manual.

Who Needs This Product
The 1042-W anchors one worker at up to 340 lb including tools and equipment for fall arrest, work positioning, and fall restraint with a maximum 6 ft free fall, and serves as an anchor in engineered horizontal lifelines and window washing systems. Commercial roofers, maintenance teams, and window washing contractors install it permanently on wood, metal, or concrete structures. Each worker still wears a full body harness with an energy absorber, lanyard, or SRL meeting current OSHA, ANSI, or CSA standards, and anchors are spaced 20 to 30 ft on center.
Features
10,000 lb cast steel loop top
The No. 1090 Q235 cast loop top accepts snaphooks, carabiners, and Super Anchor HLL end anchor hardware, and never shares with two connectors.
Foam filled galvanized riser
Polyurethane foam filling and ASTM 123 hot dip galvanizing protect the riser inside and out, rated -30 to +130 degrees F.
Structural attachment only
Bolted, concrete embedded, or field welded only; screw attachment is not permitted for risers over 18 inches.
Window washing rated
Serves suspension tie-back and fall arrest anchorage under ANSI/IWCA 1-14.1 with bolted, welded, or embedded attachment.
HLL anchor rated
Anchors CRA horizontal lifelines up to 240 ft rigged to the CRA HLL Rigging Manual.
Traceable and inspectable
PID specification label, stainless threaded vent hole plug, and serial number plate on every post.
Technical Specifications
| Loop Top | No. 1090 Q235 cast steel, 1-3/8 inch inside diameter, 10,000 lb minimum tensile strength |
|---|---|
| Riser | 24 inch height, 3.0 inch O.D. Schedule 80 (0.276 inch wall), polyurethane foam filled, ASTM 123 hot dip galvanized |
| Base Plate | 16 x 16 x 5/8 inch, 12 holes (9/16 inch bolt) |
| Anchor Weight | 66 lb |
| Ultimate Strength | 5,000 lb minimum in any direction applied to the loop top |
| Proof Load | Maximum 2,500 lb on site; do not proof load screw attached anchors |
| User Capacity | 1 person at 340 lb maximum including tools and equipment; 6 ft maximum free fall |
| Attachment | Bolted, concrete embedded, or field welded only; screw attachment is not permitted for risers over 18 inches |
| Anchor Spacing | 20 to 30 ft on center; 12 ft or less for window washing |
| Temperature Rating | -30 to +130 degrees F |
| Structural Requirement | 5,000 lb or 2 times the intended fall protection load per OSHA 1910.140 |
| Compliance | ANSI Z359.18-17 Type A/T; OSHA 1926.502; CSA Z259.15:22 Type A/T; ANSI/IWCA 1-14.1; Intertek CRA lab report available on request |
Bolted attachment required for HLL and window washing use. This 24 inch model must always be bolted, concrete embedded, or field welded; never screw attach it. The supporting structure must hold 5,000 lb or 2 times the intended load per OSHA 1910.140, and backer plates may be required when the substrate cannot carry the load alone. Field welds require a certified welder with E70XX electrode and inspection by a qualified person.
Compliance Standards
ANSI Z359.18-17 Type A/T
Anchorage connector compliance verified by Intertek lab reports per the 01-2023 CRA manual.
OSHA 1926.502 / 1910.140
Meets construction anchorage criteria with 5,000 lb structural support requirements.
CSA Z259.15:22 Type A/T
Canadian anchorage connector conformity for cross-border crews.
ANSI/IWCA 1-14.1
Window washing anchorage with engineering analysis, annual inspection, and 10 year recertification requirements.
Typical Applications
Installation Overview
Full procedures, fastener tables, and substrate figures are in the CRA manual linked below. The essentials:
- Confirm the attachment point supports 5,000 lb or 2 times the intended load, at locations specified by the project architect, engineer, or safety consultant.
- Bolted, concrete embedded, or field welded only; screw attachment is not permitted for risers over 18 inches.
- Use certified grade 8, grade 5, or 18-8 stainless bolts or A307 rod with matching lock nuts; never hot dip galvanized bolts.
- Add a plywood backer or backer plate when the primary sheathing is OSB or under 3/4 inch plywood.
- For concrete, use 1/2 inch or larger wedge bolts with flat washers in cured 2,500 PSI minimum concrete.
- Bolted window washing anchors must be proof loaded to 2,500 lb before fall protection use; the completed installation must be inspected and certified by a qualified or competent person.
Inspection and Retirement
Inspect before installation and each use, with documented annual inspections. Remove the anchor from service when any of the following apply:
- The riser is bent or deformed.
- Weld cracks are present.
- Rust that does not clean up with cold zinc coating.
- Fasteners are missing; do not use until the installation is corrected.
- The PID label or vent hole plug is missing and cannot be replaced.
- The anchor was subjected to a free fall or the supporting structure is damaged.
Tag anchors removed from service to prevent further use until inspected by a qualified or competent person.
Frequently Asked Questions
Super Anchor 1042-W Submittals and Documentation
CRA Instruction/Specification Manual 01-2023 (PDF)Materials, compliance, fastener tables, substrate installations, window washing requirements, and inspection criteria. CRA Loop Top Anchors Catalog Page (PDF)2024 catalog model table with riser heights, base plates, and weights for all CRA-W posts. CRA Horizontal Lifeline Rigging Manual (PDF)HLL end anchor rigging procedures for CRA anchor posts. Super Anchor Warranty and Compliance Statement (PDF)Manufacturer warranty terms including the 5 year permanent anchor warranty for HDG finishes.Compatible and Related Products
- Super Anchor 1028 Swivel-D Anchor. Articulating D-ring that bolts to CRA threaded top risers and other Super Anchor bases.
- Super Anchor 1031-W CRA 5" Loop Top Post. Compact 5 inch loop top post with a 6x6 base for the 1207 standing seam plate.
- Super Anchor 1031-PG CRA-PT Pass-Thru Anchor. HLL intermediate anchor for cable travel between end anchors.
- Super Anchor 1050-G HLL Rigging Kit. Galvanized rigging hardware for CRA horizontal lifelines.
Specifying Commercial Roof Anchors?
Send us the structure type, substrate, and layout and we will confirm anchor models, fastener specifications, and HLL design so the right equipment ships together, based on the delivery location.
Call 863-703-4522 to talk to a fall protection specialist.
Super Anchor Safety Manufacturer Warranty
Super Anchor Safety (SAS) warrants to the purchaser that all products are free from defect in material and workmanship at the time of shipment. This warranty is limited to product replacement for a period of one (1) year from the date of installation or use by the owner, provided that this period shall not exceed two (2) years from the date of shipment. This warranty only covers defects in material and workmanship. It does not cover conditions resulting from normal wear, neglect, abuse, or accident. This product warranty does not cover oxidation of zinc, dacromet, or powder coatings used on permanent and temporary anchors that results from connector abrasion unless the coating can be shown to be defective at the time of purchase. This warranty is non-transferable. Any unused defective product will be replaced at no charge by returning the product to Super Anchor Safety or to the distributor the product was purchased from.
Permanent Anchor Warranty
Super Anchor Safety warrants to the purchaser that all anchors sold as a permanent fixture with Hot Dip Galvanizing, Stainless Steel, and Thermo-Plastic finishes are fully warranted against failure due to defects in materials or workmanship for a period of five (5) years from the date of initial installation. SAS does not warranty the installation or flashing system used to waterproof the anchors. The SAS factory warranty is void if the product has been modified or has not been used in accordance with SAS specifications and instructions for that product. Anchors that have been removed from service due to re-roofing or remodel of the structure they were originally attached to must be inspected by an SAS factory representative or a competent person before being reinstalled.
See the Super Anchor Warranty and Compliance Statement (PDF) for the full manufacturer document.