Super Anchor 2815-T Tile Roof Retrofit Anchor 2-Pack

(No reviews yet) Write a Review
$129.60
Brand:
Super Anchor
SKU:
SA2815-T
Availability:
Usually ships in 1 business day
Shipping:
Calculated at Checkout
Bulk Pricing:
Buy in bulk and save
Adding to cart… The item has been added
Super Anchor Safety Tile-Retro

2815-T Tile-Retro Anchor for Tile Roofs, 2-Pack

The Super Anchor 2815-T Tile-Retro is the long-leg retrofit anchor for tile and slate roofs: a 40 inch, 2 inch wide, 14 gauge 430 stainless steel leg with a stamped dacromet or yellow zinc plated D-ring and a 5,000 lb minimum tensile strength. The leg conforms to the tile profile and fastens through to the top chord, permanent or temporary, on wood framed structures. This listing is a 2-pack.

Fall arrest or fall restraint anchorage for one worker at up to 340 lb including tools, with a 6 ft maximum free fall and 1,800 lb maximum arrest force with the required energy absorber. Compliant with OSHA 1926.502 and 1910.66, ANSI Z359.1-07 and A10.32-2012 per the 2025 Tile-Retro manual.

Super Anchor 2815-T anchor D-ring exposed at the ridge of a finished tile roof
5,000 lbAnchor Leg and D-Ring Tensile
340 lbUser Capacity with Tools
40 inAnchor Leg Length
16 / 10Fasteners Low Profile / Tile
6 ftMaximum Free Fall
2.0 inLeg Width
430 SST14 Gauge Stainless Leg
2xAnchors per Pack

Who Needs This Product

The Tile-Retro is for crews working on high profile tile, S-tile, and slate roofs when penetrating clean tile courses is not an option: solar installers, roof maintenance, and re-roofing contractors. The 40 inch leg runs from the top chord fastening zone up over the ridge line area so the D-ring stays accessible above the tile courses. Each worker wears a full body harness with a personal energy absorber sized for the user weight, on a lifeline or SRL. Not for window washing, work positioning, or horizontal lifeline systems.

Features

40 inch conforming leg

The 14 gauge stainless leg bends to follow the tile profile, with the top 6 fastener holes used for high profile tiles.

Fastens to the top chord

3 inch spiral stainless nails or screws through 7/16 inch OSB or plywood sheathing into a minimum 2x4 top chord.

Two fastener schedules

16 fasteners over low profile and asphalt shingles, or 10 fasteners using the top holes for high profile tiles per Tables 1 and 2.

340 lb user rating

Rated above the standard 310 lb for heavier workers with full tool loads.

Permanent or temporary

Install during re-roofing and leave for future maintenance access, or remove after the job.

Blow-out inspection design

Fastener blow-outs show on the framing underside at first installation for a fast verification check.

Technical Specifications

ModelTile-Retro No. 2815T
Package2-pack
Anchor Leg14 gauge 430 stainless steel, 40 x 2.0 inches
D-Ring2-1/2 inch, stamped dacromet or yellow zinc plated steel
Minimum Tensile Strength5,000 lb anchor leg and D-ring
User Capacity1 person at 340 lb maximum including tools and equipment
Maximum Free Fall6 ft; 1,800 lb maximum arrest force with required energy absorber
Fasteners3 inch SST spiral nails, or hex and bugle head screws at lowest torque; 16 total low profile, 10 total high profile tile
Framing RequirementMinimum 2x4 top chord with 7/16 inch OSB or plywood sheathing supporting 5,000 lb or 2 times the intended load
ComplianceOSHA 1926.502 and 1910.66; ANSI Z359.1-07; ANSI A10.32-2012
Use RestrictionsNot for window washing, work positioning, or horizontal lifelines; never install over open framing without sheathing

Never install over open framing. Framing must support 5,000 lb or 2 times the intended load, with the leg installed over a minimum 2x4 top chord with structurally sound 7/16 inch OSB or plywood sheathing. Position leg center fastener holes over the top chord center, angle off-center fasteners toward the chord, and remove and relocate any anchor showing fastener blow-outs. Never install screws by hammering and never reuse fasteners.

Compliance Standards

ANSI Z359.1-07 / A10.32-2012

Anchorage compliance for construction fall protection per the 2025 Tile-Retro manual.

OSHA 1926.502 / 1910.66

Meets construction and powered platform anchorage criteria.

430 Stainless Construction

14 gauge stainless leg with plated forged D-ring, stamped with date of manufacture.

Super Anchor Fastener System

Factory supplied fastener packs with engineering support for alternate fasteners.

Typical Applications

Tile Re-RoofingAnchors installed on underlayment as tile goes down.
S-Tile and High ProfileTop-hole fastener schedule keeps the D-ring accessible.
Slate RoofsLong leg spans courses without breaking slates.
Solar on TileTie-off for array installation and service.
Ridge MaintenancePermanent D-ring access above the tile line.
Fall RestraintPerimeter rigging without free fall exposure.
Skylight WorkAnchorage near roof openings.
InspectionsAccess anchors for estimators and inspectors.

Installation Overview

Full figures and fastener tables are in the 2025 Tile-Retro manual linked below. The basics:

  1. Confirm the framing: minimum 2x4 top chord with sound 7/16 inch OSB or plywood sheathing, capable of 5,000 lb or 2 times the intended load.
  2. Position the leg with its center fastener holes over the top chord center, D-ring at the ridge area above the tile courses.
  3. Low profile roofing: drive all 16 fasteners (8 per leg zone). High profile tile: use the top 6 fastener holes with 10 total fasteners per Table 2.
  4. Conform the leg to the tile profile as tiles install over it, removing tile underside material where needed for proper fit.
  5. Caulk the overlap to prevent wind driven particles and water penetration, and set the D-ring exposure before the final courses.
  6. Check the framing underside for fastener blow-outs and verify the installation before first use.

Inspection and Retirement

Inspect before installation and each use, with documented annual inspections. Remove the anchor from service when any of the following apply:

  • The D-ring or shackle is deformed.
  • Fasteners are missing per the Table 1 or Table 2 schedule.
  • Fastener blow-outs appear on the framing underside; remove and relocate the anchor.
  • The anchor was subjected to a free fall.
  • The PID label is missing or illegible.

Tag anchors removed from service to prevent further use until inspected by a qualified or competent person.

Fall Protection Distributors logo Fall Protection
Distributors, LLC
Free Tool · No Signup · OSHA 1926.502
Free Interactive Tool Fall Protection Calculator Pick your system. Run the math. Generate a plan. 1Pick Your SystemDetermine fall restraint vs. fall arrest based on your work surface, edge access, and clearance. 2Run the MathCalculate exact fall clearance required below the work surface for your SRL or lanyard setup. 3Generate a PlanGet a printable OSHA-compliant Fall Protection Plan structured around 29 CFR 1926.502(k). Run the Numbers and Stay Safe Launch the Calculator ›

Frequently Asked Questions

How does the Tile-Retro attach on a tile roof?
The 40 inch leg fastens through the sheathing into the top chord below the tile, conforms over the battens and tile profile, and leaves the 2-1/2 inch D-ring exposed at the ridge area. High profile tiles use the top 6 fastener holes with 10 total fasteners. Follow the recommended fastener pattern and placement so the connection is secure, and re-check the installation before you rely on it for fall arrest.
Is this the same as the RS-20 tile installation?
They overlap: the RS-20 is a 17-1/2 inch anchor that also installs on tile, while the Tile-Retro runs 40 inches for high profile tiles that need more reach to keep the D-ring accessible. For mixed roofs, the RS series manual and Tile-Retro manual both apply. Follow the recommended fastener pattern and placement so the connection is secure, and re-check the installation before you rely on it for fall arrest.
What is the user weight rating?
340 lb maximum for one person including tools and equipment, with a 6 ft maximum free fall and a personal energy absorber specified for the user weight, per the 2025 manual. Refer to the specification table above for full details on construction, finish, and sizing.
Can it stay on the roof permanently?
Yes, the anchor installs permanently or temporarily on wood framed structures. Permanent installations get caulked fastener heads and overlap protection against wind driven water. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off. A qualified person should verify that the installation and the overall system meet the requirements of your specific job site.
What fasteners does it use?
Super Anchor supplied 3 inch SST spiral nails, or hex and bugle head screws driven at the lowest torque setting. Never substitute other fasteners without engineering, never hammer screws, and never reuse fasteners. Verify that the mounting surface is sound and that every fastener is fully seated before the anchor is put into service.
What do I inspect before use?
D-ring and shackle condition, the full fastener schedule, and the framing underside for blow-outs at first installation. Remove the anchor from service after any free fall. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off. Store it in a clean, dry place away from heat and chemicals to help preserve its condition between uses.
What PPE pairs with this anchor?
A full body harness with a personal energy absorber rated for the user weight, connected by a vertical lifeline with rope grab or an SRL, using snaphooks or carabiners with 3,600 lb gates meeting current ANSI or CSA standards. Make sure the connecting hardware and anchorage suit your application before you attach a lanyard or lifeline.

Working on Tile Roofs?

Send us the tile profile and roof layout and we will confirm anchor counts, fastener schedules, and lifelines so everything ships together, based on the delivery location.

Call 863-703-4522 to talk to a fall protection specialist.

Super Anchor Safety Manufacturer Warranty

Super Anchor Safety (SAS) warrants to the purchaser that all products are free from defect in material and workmanship at the time of shipment. This warranty is limited to product replacement for a period of one (1) year from the date of installation or use by the owner, provided that this period shall not exceed two (2) years from the date of shipment. This warranty only covers defects in material and workmanship. It does not cover conditions resulting from normal wear, neglect, abuse, or accident. This product warranty does not cover oxidation of zinc, dacromet, or powder coatings used on permanent and temporary anchors that results from connector abrasion unless the coating can be shown to be defective at the time of purchase. This warranty is non-transferable. Any unused defective product will be replaced at no charge by returning the product to Super Anchor Safety or to the distributor the product was purchased from.

Permanent Anchor Warranty

Super Anchor Safety warrants to the purchaser that all anchors sold as a permanent fixture with Hot Dip Galvanizing, Stainless Steel, and Thermo-Plastic finishes are fully warranted against failure due to defects in materials or workmanship for a period of five (5) years from the date of initial installation. SAS does not warranty the installation or flashing system used to waterproof the anchors. The SAS factory warranty is void if the product has been modified or has not been used in accordance with SAS specifications and instructions for that product. Anchors that have been removed from service due to re-roofing or remodel of the structure they were originally attached to must be inspected by an SAS factory representative or a competent person before being reinstalled.

See the Super Anchor Warranty and Compliance Statement (PDF) for the full manufacturer document.

About Super Anchor

Founded in 1992 by Steve Nichols, Super Anchor patented and released the A.R.S. Super Anchor, the first permanent roof anchorage device in its innovative P.P.E. line. The A.R.S. Super Anchor remains a top seller today under A.R.S. 2x8 and 2x4 anchors. Drawing from over 20 years of roofing experience, Super Anchor's founder recognized the industry's need for specialized fall protection tailored to roofers. Still family-owned and operated, Super Anchor provides premium fall arrest equipment such as harnesses, anchors, rooftop posts, and self-retracting lifelines. Steve Nichols is still at the helm, leading Super Anchor as it innovates new products yearly. Headquartered in Monroe, Washington, the company prioritizes innovation, superior customer service, and products that exceed standards. Super Anchor Safety exemplifies pioneering fall protection born from real-world roofing expertise. The company motto will remain "The Best In Fall Arrest" regarding the products it sells and the customer service it provides.

Related Products