Installation Screws for CB Anchor Points, 4-Pack
Guardian anchor installations live and die by their fasteners, and these are the factory-specified screws for CB-series anchor points: #14-10 x 2 in galvanized screws (00668) for wood substrates, and #14-14 x 2 in self-sealing hex head screws in 40-count bags (00669) for metal roofs and decks.
Each option ships as a 4-pack of the factory unit. Using the specified fastener keeps the anchor installation inside its tested configuration.

Who Needs This Product
Fastener substitution is the quiet killer of anchor ratings: the test report assumes the factory screw, and a jobsite substitute changes the whole calculation. Stocking factory screw packs means reinstalls and new installations stay inside the tested configuration, and the self-sealing metal screws keep the deck watertight where they land.
Features
Bag of 40 screws
Bag of 40 screws
Wood and metal deck screws available
Wood and metal deck screws available
#14-10 x 2" galvanized screws for wood
#14-10 x 2" galvanized screws for wood
Jobsite-grade construction
Built with the materials and finish quality Guardian applies across its height safety line.
Documented compliance
Full manufacturer documentation is linked on this page for submittal packages.
Fleet-friendly inspection
Clear inspection criteria in the manual keep competent-person checks fast and consistent.
Options in This Family
| SKU | Description |
|---|---|
| 00668-4PK | Guardian CB Anchor Installation Screws, 4-Pack, #14-10 x 2 in galvanized, wood (4-Pack) |
| 00669-4PK | Guardian CB Anchor Installation Screws, 4-Pack, #14-14 x 2 in self-sealing, metal (40-count bag) (4-Pack) |
Technical Specifications
| SKU | 00668-4PK / 00669-4PK |
|---|---|
| Materials | Galvanized Steel |
| Product weight | 1.1 lbs |
| Dimensions | 14 in L x 10 in W x 9 in H |
| Warranty | Guardian lifetime warranty against defects in material and workmanship |
Anchorage strength is the foundation of the system. The structure and anchor must withstand 5,000 lbs per attached worker or maintain a 2:1 safety factor under qualified-person supervision. Verify substrate, fastener, and orientation requirements against the instruction manual before every installation.
Compliance Standards
OSHA 1926.502
This product is compliant with OSHA 1926.502 when used as part of a complete, competent-person verified system.
OSHA 1910.140
This product is compliant with OSHA 1910.140 when used as part of a complete, competent-person verified system.
ISO 17025 lab tested
Guardian products are tested in an ISO 17025 accredited laboratory; available documentation is linked below.
Typical Applications
Installation Overview
Installation must follow the Guardian instruction manual for this anchor. The sequence below is an overview only.
- Inspect first. Check the anchor body, connection point, and hardware before every installation.
- Verify the structure. The supporting structure must meet the strength requirements in the instruction manual.
- Install per the manual. Follow the substrate, fastener, and orientation requirements exactly; fill every required fastener position.
- Verify the connection. Confirm the anchor is fully seated and the connection point is accessible and undamaged.
- Connect the system. Attach a compatible connecting device and verify the complete personal fall arrest system with a competent person.
- Check clearance. Confirm fall clearance below the work area and minimize swing fall hazards before work begins.
Inspection and Retirement
Inspect before every use, and have a competent person perform a documented inspection at least every six months under ANSI Z359.2 practice. Remove the anchor from service for any of the conditions below.
- Cracks, corrosion, or deformation of the body, connection point, or welds.
- Loose, missing, damaged, or worn hardware and fasteners.
- Elongation or wear at the D-ring or connection eye.
- Missing or illegible labels.
- Any evidence the anchor has arrested a fall.
Retirement triggers: any fall event on the anchor, or any condition where the inspector cannot positively verify it is fit for service.
Frequently Asked Questions
Guardian CB Anchor Installation Screws, 4-Pack Submittals and Documentation
Guardian 00205 Inspection Form (PDF)Printable competent-person inspection checklist.Compatible and Related Products
- Guardian External Shock Absorbing Lanyard 2-Pack. Connecting devices for anchored workers.
- Guardian 10900 Halo 11 ft Web SRL. Short-clearance SRL for overhead anchorage.
- Guardian 00455 Temper Roof Anchor 4-Pack. Reusable residential roof anchors.
Specifying Anchors for Your Jobsite?
Substrate, structure, and system layout decide the right anchor. Confirm your application with us and we will make sure the right equipment ships together, based on the delivery location.
Call 863-703-4522 to talk to a fall protection specialist.
Guardian Fall Protection Manufacturer Warranty
Guardian warrants to the purchaser that all products are free from defects in material, workmanship, and design (when the design is Guardian's responsibility). This warranty does not cover conditions resulting from normal wear and tear, neglect, abuse, accident, or otherwise. Guardian's obligations under this warranty apply for the lifetime of the product and are limited to the replacement of the product only.
This warranty is not transferable and does not apply to product that is resold after having been put into service. The warranty is void if the product is changed or altered in any way, or if the product is used in a manner other than for which it is intended. No other person, firm, or entity is authorized to assume or assign for Guardian any other liability in connection with the sale or use of Guardian products. There are no implied warranties of merchantability or fitness for a particular purpose.
Source: Guardian Standard Terms and Conditions of Sale, Doc. 102 v3.0. Contact Guardian customer service at +1 (800) 466-6385 or through guardianfall.com for warranty claims and product support.