Super Anchor 1001 ARS Permanent Anchor 6-Pack – Stainless Steel Roof Anchors
The Super Anchor 1001 ARS Permanent Anchor 6-Pack provides six industry-leading anchors trusted by residential and commercial builders for over 25 years. Designed for installation during the framing stage, these anchors are flashed directly into the roofing material to provide a permanent, discreet fall-protection tie-off point for the life of the structure. The ARS 2x8 anchor is versatile enough to be compatible with 2x4, 2x6, 2x8, and even larger 2x10 or 2x12 trusses via the drill-through attachment method. For smaller projects requiring fewer units, we also offer the Super Anchor 2801 ARS 2-Pack.
Planning a permanent safety layout? Modern roofing requires precise engineering for long-term compliance. Let our experts provide a free engineered plan for your site. Submit an HLL Quote Request Form Here.

Engineered for Weatherproof Performance and Durability
The 1001 ARS system is built for durability, compliance, and ease of installation. Crafted from high-quality 14-gauge 430 stainless steel, each anchor features exceptional tensile strength and corrosion resistance. The system includes a specialized, injection-molded TPE (Thermoplastic Elastomer) flashing base. This creates a secondary weatherproof seal that integrates seamlessly with asphalt shingles or wood shakes, ensuring the anchor provides safety without ever becoming a source of roof leaks. To complete your fall arrest system, pair these anchors with a high-performance Super Anchor 4015-Z Rope Grab for reliable vertical mobility.
Framing-Stage Installation for 2026 Standards
These anchors are designed to be bolted directly to the truss or rafter during the framing phase. Using the factory-supplied Grade 8 bolt and locknut, the ARS provides a structural connection that meets or exceeds the 5,000-pound breaking strength required by OSHA and ANSI. Because it attaches directly to the structural members, no additional blocking is required for 2x8 trusses, saving time and material costs on the job site. Once the roof is finalized, only the low-profile stem is visible, which provides a safe tie-off point for workers using a Super Anchor 6101GH Harness.

1001 ARS Technical Specifications:
- Material: 14-Gauge 430 Stainless Steel
- Tensile Strength: 5,000 lbs Minimum Breaking Strength
- Truss Compatibility: 2x4 through 2x12 Trusses/Rafters
- Flashing System: Injection-molded TPE (Weatherproof)
- Fasteners: 5/16”-18 x 2-1/4” Grade 8 Bolt with Locknut
- User Capacity: 340 lbs (including tools and equipment)
- Compliance: OSHA 1926:502, ANSI Z359.18-17 Type D, CSA Z259.11-05
Super Anchor 1001 ARS Technical Resources:
- Super Anchor ARS Instruction Manual – Essential guide for correct fastener placement and flashing integration.
Super Anchor 1001 ARS Permanent Anchor FAQ
1. Can I install the ARS anchor on an existing roof?
The ARS series is strictly designed for installation during the framing stage or during a full "tear-off" re-roofing project. The anchor must be bolted directly to the truss before the roof sheathing and material are installed to ensure it is properly flashed and structurally sound.
2. How many anchors are included in this pack?
The 1001 product code refers to a 6-pack of anchors. This is the most cost-effective way for contractors to outfit a standard residential roof with a complete permanent fall protection system.
3. Is the flashing compatible with tile roofs?
The standard TPE flashing included in the 1001 kit is designed for asphalt shingle and wood shake roofs. For tile applications, you may require a specialized flashing kit or lead flashing. We recommend checking the Super Anchor ARS Instruction Manual for tile-specific guidance.
4. Does this anchor support more than one person?
No. The ARS is a single-user anchor point. It is rated for one worker (up to 340 lbs) for either fall arrest or fall restraint. Never attach multiple lifelines or workers to a single anchor stem.
5. How do I choose between the ARS 2x4 and 2x8 models?
The model name refers to the length of the anchor stem. The 2x8 (1001) model is slightly longer, making it suitable for thicker roofing assemblies or when you want the anchor point to sit higher above the shingles for easier access. Both are compatible with standard 2x4 trusses.
6. Is maintenance required for a permanent anchor?
OSHA requires all permanent anchors to be inspected by a "competent person" before each use and annually. This ensures that the flashing remains watertight and the structural connection remains secure.
7. How do I avoid common mistakes during installation?
- 1. Fastener Substitution: Only use the provided Grade 8 hardware. Standard bolts do not have the shear strength required to meet the 5,000 lb rating.
- 2. Flashing Layering: Always "shingle" the flashing base. The top of the flashing should be under the shingle above it, and the bottom should be over the shingle below it to shed water correctly.
- 3. Stem Alignment: Ensure the anchor stem is plumb (vertical) before tightening the bolt to ensure it exits the roof sheathing at the correct angle.